MADE 3.9.1 User Manual > Report Generation > Criticality Reports
FMECA (HRI, Custom)
The Failure Mode Effects and Criticality Analysis (Hazard Risk Index, Custom) report
or FMECA (HRI, Custom) report is based on the HRI criticality method defined in
ABR-6303, tailored by a customer for a MER process. This report is a variation on the
standard HRI report that uses a unique Item ID and Failure Mode ID system, adds a
mission effects column and identifies whether items should be carried forwards in the
analysis process based on a criticality threshold.
[Image: FMECA-HRIcustom.png]
Analysis Options
The user sets the end effect item according to the expected system output required
by selecting an element from the provided end effect item list followed by selecting
the "Set End Effect Item" button or from the system model, followed by
selecting the "Next" button. (alternatively, right-click on a selected item
in the system model and select "End Effect Item" from the menu).
[Image: AnalysisOptions.png]
Report Body Customization
The next page following Analysis Options will help define the report formatting
including page size, orientation and a customizable page footer.
[Image: ReportCustom.png]
Cover Page Details
The Cover Page Organisation Details page following Analysis Options will help define
the report formatting including page size, orientation and a customizable page footer.
[Image: OrganizationDetails.png]
Sample Report
[Image: FMECA-HRI.png]
Source: Local MADE 3.9.1 installation: com.phm.made.help.plugin/documents/help/html/MADeHelp/14-ReportGeneration/01CriticalityReports/04FMECA-HRICustom.html · retrieved 2026-07-09